| Parameter | Value |
|---|---|
| Orderable part number | DRA74-331-R |
| Rated inductance | 330 uH ±20% |
| Open circuit inductance (OCL) | 329 uH |
| Irms (40 °C rise) | 0.43 A |
| Isat1 (30% rolloff @ +25 °C) | 0.51 A |
| Isat2 (40% rolloff @ +125 °C) | 0.41 A |
| DCR typical @ 20 °C | 1500 mOhm |
| DCR maximum @ 20 °C | 1790 mOhm |
| K-factor (Bp-p = K x L x dI) | 15.3 |
| Package | 7.6 x 7.6 mm footprint |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
This is the automotive grade version of the drum core family: AEC-Q200 qualified, shielded, and rated to 165 °C including self-temperature rise. The electrical behaviour is familiar; the qualification and the mechanical build are not.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRA74 shares the 7.6 mm pad with DRA73 and stands taller, which is how it reaches the higher current ratings in this size. AEC-Q200, 165 °C, shielded.
330 uH sits in the middle of the range, and the trade at that point is explicit: 1500 mOhm of DCR against 0.51 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
Design note: the 165 °C rating is ambient plus self-heating. Close the loss budget at the hot corner, with the maximum DCR and the hot Isat figure.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd