| Parameter | Value |
|---|---|
| Orderable part number | DRAQ127-150-R |
| Rated inductance | 15 uH ±20% |
| Open circuit inductance (OCL) | 14.9 uH |
| Irms (40 °C rise) | 4.83 A |
| Isat1 (30% rolloff @ +25 °C) | 9.03 A |
| Isat2 (40% rolloff @ +125 °C) | 7.23 A |
| DCR typical @ 20 °C | 27 mOhm |
| DCR maximum @ 20 °C | 32 mOhm |
| K-factor (Bp-p = K x L x dI) | 19.4 |
| Series connection | 59.6 uH, 2.41 A |
| Parallel connection | 15 uH, 4.83 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 x 8.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAQ127 is the large dual-winding automotive part: 12.5 x 12.5 x 8.0 mm, AEC-Q200, 200 Vac winding isolation, and enough copper to run tens of amps in parallel mode.
15 uH sits in the middle of the range, and the trade at that point is explicit: 27 mOhm of DCR against 9.03 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd