| Parameter | Value |
|---|---|
| Orderable part number | DRAQ127-220-R |
| Rated inductance | 22 uH ±20% |
| Open circuit inductance (OCL) | 22 uH |
| Irms (40 °C rise) | 3.98 A |
| Isat1 (30% rolloff @ +25 °C) | 7.57 A |
| Isat2 (40% rolloff @ +125 °C) | 6.05 A |
| DCR typical @ 20 °C | 40 mOhm |
| DCR maximum @ 20 °C | 47 mOhm |
| K-factor (Bp-p = K x L x dI) | 16.2 |
| Series connection | 88 uH, 1.99 A |
| Parallel connection | 22 uH, 3.98 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 x 8.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
The DRQ/DRAQ construction puts two windings on a shielded drum core with a defined 1:1 turns ratio. That ratio is what makes the part useful as a transformer: the two windings share flux, so the magnetising current is common and the ripple can be made to cancel.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRAQ127 is the large dual-winding automotive part: 12.5 x 12.5 x 8.0 mm, AEC-Q200, 200 Vac winding isolation, and enough copper to run tens of amps in parallel mode.
22 uH sits in the middle of the range, and the trade at that point is explicit: 40 mOhm of DCR against 7.57 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.