| Parameter | Value |
|---|---|
| Orderable part number | DRAQ127-470-R |
| Rated inductance | 47 uH ±20% |
| Open circuit inductance (OCL) | 47.9 uH |
| Irms (40 °C rise) | 2.62 A |
| Isat1 (30% rolloff @ +25 °C) | 5.09 A |
| Isat2 (40% rolloff @ +125 °C) | 4.07 A |
| DCR typical @ 20 °C | 91 mOhm |
| DCR maximum @ 20 °C | 110 mOhm |
| K-factor (Bp-p = K x L x dI) | 10.9 |
| Series connection | 192 uH, 1.31 A |
| Parallel connection | 47 uH, 2.62 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 x 8.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAQ127 is the large dual-winding automotive part: 12.5 x 12.5 x 8.0 mm, AEC-Q200, 200 Vac winding isolation, and enough copper to run tens of amps in parallel mode.
At 47 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 91 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd