| Parameter | Value |
|---|---|
| Orderable part number | DRAQ75-100-R |
| Rated inductance | 10 uH ±20% |
| Open circuit inductance (OCL) | 9.59 uH |
| Irms (40 °C rise) | 3.47 A |
| Isat1 (30% rolloff @ +25 °C) | 2.97 A |
| Isat2 (40% rolloff @ +125 °C) | 2.38 A |
| DCR maximum @ 20 °C | 52 mOhm |
| K-factor (Bp-p = K x L x dI) | 84.9 |
| Series connection | 38.3 uH, 1.73 A |
| Parallel connection | 10 uH, 3.47 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAQ75 is an AEC-Q200 dual-winding drum core in a 7.6 x 7.6 x 4.5 mm body, with 500 Vdc isolation between windings. Parallel for current, series for inductance, coupled for a 1:1 transformer in a SEPIC or flyback.
Choose 10 uH when the ripple target is in the middle of the design window: the DCR stays at - mOhm and the saturation limit at 2.97 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.