| Parameter | Value |
|---|---|
| Orderable part number | DRAQ75-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 98.3 uH |
| Irms (40 °C rise) | 1.14 A |
| Isat1 (30% rolloff @ +25 °C) | 0.91 A |
| Isat2 (40% rolloff @ +125 °C) | 0.72 A |
| DCR maximum @ 20 °C | 478 mOhm |
| K-factor (Bp-p = K x L x dI) | 25.5 |
| Series connection | 393 uH, 0.57 A |
| Parallel connection | 100 uH, 1.14 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAQ75 is an AEC-Q200 dual-winding drum core in a 7.6 x 7.6 x 4.5 mm body, with 500 Vdc isolation between windings. Parallel for current, series for inductance, coupled for a 1:1 transformer in a SEPIC or flyback.
At 100 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the - mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd