| Parameter | Value |
|---|---|
| Orderable part number | DRAQ75-170-R |
| Rated inductance | 17 uH ±20% |
| Open circuit inductance (OCL) | 18.7 uH |
| Irms (40 °C rise) | 2.48 A |
| Isat1 (30% rolloff @ +25 °C) | 2.14 A |
| Isat2 (40% rolloff @ +125 °C) | 1.71 A |
| DCR maximum @ 20 °C | 102 mOhm |
| K-factor (Bp-p = K x L x dI) | 61.2 |
| Series connection | 68.5 uH, 1.24 A |
| Parallel connection | 17 uH, 2.48 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAQ75 is an AEC-Q200 dual-winding drum core in a 7.6 x 7.6 x 4.5 mm body, with 500 Vdc isolation between windings. Parallel for current, series for inductance, coupled for a 1:1 transformer in a SEPIC or flyback.
Choose 17 uH when the ripple target is in the middle of the design window: the DCR stays at - mOhm and the saturation limit at 2.14 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.