Eaton DRAQ75-221-R - Dual Winding 220 uH Power Inductor
Eaton DRAQ75-221-R - Dual Winding 220 uH Power Inductor

Eaton DRAQ75-221-R - Dual Winding 220 uH Power Inductor

Share
Eaton DRAQ75-221-R: AEC-Q200 Dual Winding Automotive Drum Core Inductor, 220 uH, 0.76 A, DCR 1.09 ohm.
    • Product Details
    • Download

    Eaton DRAQ75-221-R - Dual Winding 220 uH Power Inductor

    DRAQ75-221-R at a glance: dual-winding shielded drum core, 220 uH per winding, 0.76 A, DCR 1090 mOhm max.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAQ75-221-R
    Rated inductance220 uH ±20%
    Open circuit inductance (OCL)217 uH
    Irms (40 °C rise)0.76 A
    Isat1 (30% rolloff @ +25 °C)0.63 A
    Isat2 (40% rolloff @ +125 °C)0.5 A
    DCR maximum @ 20 °C1090 mOhm
    K-factor (Bp-p = K x L x dI)17.4
    Series connection866 uH, 0.38 A
    Parallel connection220 uH, 0.76 A
    Turns ratio1:1, coupled
    Package7.6 x 7.6 x 4.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.

    In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    Series Positioning

    DRAQ75 is an AEC-Q200 dual-winding drum core in a 7.6 x 7.6 x 4.5 mm body, with 500 Vdc isolation between windings. Parallel for current, series for inductance, coupled for a 1:1 transformer in a SEPIC or flyback.

    • Typical applications: Automotive LED drivers, body control modules, SEPIC and flyback converters, filter chokes.
    • 500 Vdc winding isolation is the highest in this group - it is still a functional rating, not reinforced insulation for a mains barrier.
    • Data sheet 11017.

    Sizing and Layout Notes

    Choose 220 uH when the ripple target is in the middle of the design window: the DCR stays at - mOhm and the saturation limit at 0.63 A leaves the transient room it needs.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Can I use it as a flyback transformer?
    Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.

    How much isolation is there between windings?
    The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.

    Does the coupling ratio matter?
    Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.

    Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

    Mechanical Dimensions

    eaton-draq75-automotive-shieleded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.