| Parameter | Value |
|---|---|
| Orderable part number | DRAQ75-810-R |
| Rated inductance | 81 uH ±20% |
| Open circuit inductance (OCL) | 80.9 uH |
| Irms (40 °C rise) | 1.2 A |
| Isat1 (30% rolloff @ +25 °C) | 1.01 A |
| Isat2 (40% rolloff @ +125 °C) | 0.81 A |
| DCR maximum @ 20 °C | 431 mOhm |
| K-factor (Bp-p = K x L x dI) | 28.9 |
| Series connection | 324 uH, 0.6 A |
| Parallel connection | 81 uH, 1.2 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 x 4.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRAQ75 is an AEC-Q200 dual-winding drum core in a 7.6 x 7.6 x 4.5 mm body, with 500 Vdc isolation between windings. Parallel for current, series for inductance, coupled for a 1:1 transformer in a SEPIC or flyback.
81 uH sits in the middle of the range, and the trade at that point is explicit: - mOhm of DCR against 1.01 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: parallel and series ratings differ by about 4x. Read the column that matches the connection you intend to use, and keep the winding isolation rating in mind.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.