| Parameter | Value |
|---|---|
| Orderable part number | DRQ125-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 103 uH |
| Irms (40 °C rise) | 1.78 A |
| Isat | 2.2 A |
| DCR typical @ 20 °C | 170 mOhm |
| Volt-microsecond rating | 47.5 V-us |
| Series connection | 411 uH, 0.89 A |
| Parallel connection | 100 uH, 1.78 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ125 is the 12.5 mm dual-winding part at 6.0 mm height. Wire the windings in parallel for a high-current single inductor, in series for a high-inductance choke, or leave them coupled as a 1:1 transformer for a SEPIC or flyback.
100 uH sits in the middle of the range, and the trade at that point is explicit: 170 mOhm of DCR against 2.2 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd