| Parameter | Value |
|---|---|
| Orderable part number | DRQ127-470-R |
| Rated inductance | 47 uH ±20% |
| Open circuit inductance (OCL) | 47 uH |
| Irms (40 °C rise) | 2.95 A |
| Isat | 5.28 A |
| DCR typical @ 20 °C | 71.9 mOhm |
| Volt-microsecond rating | 37.1 V-us |
| Series connection | 188 uH, 1.47 A |
| Parallel connection | 47 uH, 2.95 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The DRQ/DRAQ construction puts two windings on a shielded drum core with a defined 1:1 turns ratio. That ratio is what makes the part useful as a transformer: the two windings share flux, so the magnetising current is common and the ripple can be made to cancel.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRQ127 is the tallest dual-winding DRQ at 8.0 mm and the highest-current part in the family, up to 56 A peak in parallel mode. Two windings, one core, and the option to use it as a transformer.
47 uH sits in the middle of the range, and the trade at that point is explicit: 71.9 mOhm of DCR against 5.28 A of saturation headroom.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.