| Parameter | Value |
|---|---|
| Orderable part number | DRQ127-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 677 uH |
| Irms (40 °C rise) | 0.76 A |
| Isat | 1.39 A |
| DCR typical @ 20 °C | 1080 mOhm |
| Volt-microsecond rating | 141 V-us |
| Series connection | 2707 uH, 0.38 A |
| Parallel connection | 680 uH, 0.76 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ127 is the tallest dual-winding DRQ at 8.0 mm and the highest-current part in the family, up to 56 A peak in parallel mode. Two windings, one core, and the option to use it as a transformer.
Choose 680 uH when the ripple target is in the middle of the design window: the DCR stays at 1080 mOhm and the saturation limit at 1.39 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.