| Parameter | Value |
|---|---|
| Orderable part number | DRQ127-821-R |
| Rated inductance | 820 uH ±20% |
| Open circuit inductance (OCL) | 818 uH |
| Irms (40 °C rise) | 0.65 A |
| Isat | 1.27 A |
| DCR typical @ 20 °C | 1470 mOhm |
| Volt-microsecond rating | 155 V-us |
| Series connection | 3272 uH, 0.33 A |
| Parallel connection | 820 uH, 0.65 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRQ127 is the tallest dual-winding DRQ at 8.0 mm and the highest-current part in the family, up to 56 A peak in parallel mode. Two windings, one core, and the option to use it as a transformer.
820 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd