| Parameter | Value |
|---|---|
| Orderable part number | DRQ73-1R5-R |
| Rated inductance | 1.5 uH ±20% |
| Open circuit inductance (OCL) | 1.48 uH |
| Irms (40 °C rise) | 4.64 A |
| Isat | 6.52 A |
| DCR typical @ 20 °C | 13.2 mOhm |
| Volt-microsecond rating | 4.36 V-us |
| Series connection | 5.93 uH, 2.32 A |
| Parallel connection | 1.5 uH, 4.64 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.
1.5 uH sits in the middle of the range, and the trade at that point is explicit: 13.2 mOhm of DCR against 6.52 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.