| Parameter | Value |
|---|---|
| Orderable part number | DRQ73-821-R |
| Rated inductance | 820 uH ±20% |
| Open circuit inductance (OCL) | 822 uH |
| Irms (40 °C rise) | 0.27 A |
| Isat | 0.28 A |
| DCR typical @ 20 °C | 3930 mOhm |
| Volt-microsecond rating | 103 V-us |
| Series connection | 3287 uH, 0.13 A |
| Parallel connection | 820 uH, 0.27 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The DRQ/DRAQ construction puts two windings on a shielded drum core with a defined 1:1 turns ratio. That ratio is what makes the part useful as a transformer: the two windings share flux, so the magnetising current is common and the ripple can be made to cancel.
Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.
820 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd