Eaton DRQ73-8R2-R 8.2 uH Coupled Drum Core Inductor
Eaton DRQ73-8R2-R 8.2 uH Coupled Drum Core Inductor

Eaton DRQ73-8R2-R 8.2 uH Coupled Drum Core Inductor

Share
Eaton DRQ73-8R2-R: Dual Winding Shielded Drum Core Inductor, 8.2 uH, 2.19 A, DCR 59.2 mOhm.
    • Product Details
    • Download

    Eaton DRQ73-8R2-R 8.2 uH Coupled Drum Core Inductor

    DRQ73-8R2-R at a glance: dual-winding shielded drum core, 8.2 uH per winding, 2.19 A, DCR 59.2 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRQ73-8R2-R
    Rated inductance8.2 uH ±20%
    Open circuit inductance (OCL)8.93 uH
    Irms (40 °C rise)2.19 A
    Isat2.66 A
    DCR typical @ 20 °C59.2 mOhm
    Volt-microsecond rating10.7 V-us
    Series connection35.7 uH, 1.1 A
    Parallel connection8.2 uH, 2.19 A
    Turns ratio1:1, coupled
    Package7.6 x 7.6 mm footprint, 3.55 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.

    In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.

    Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    What This Family Is For

    DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.

    • Typical applications: Buck and boost stages, SEPIC and flyback transformers, output filters, LCD panels, portable devices.
    • The two windings are isolated to 200 Vac only - this is a functional barrier for circuit reasons, not a safety isolation rating.
    • Data sheet DS4311.

    Design Notes

    Choose 8.2 uH when the ripple target is in the middle of the design window: the DCR stays at 59.2 mOhm and the saturation limit at 2.66 A leaves the transient room it needs.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What happens if I only use one winding?
    The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.

    Can I use it as a flyback transformer?
    Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.

    Does the coupling ratio matter?
    Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.

    Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

    Mechanical Dimensions

    eaton-drq-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.