| Parameter | Value |
|---|---|
| Orderable part number | DRQ74-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 102 uH |
| Irms (40 °C rise) | 0.86 A |
| Isat | 0.99 A |
| DCR typical @ 20 °C | 383 mOhm |
| Volt-microsecond rating | 31.8 V-us |
| Series connection | 406 uH, 0.43 A |
| Parallel connection | 100 uH, 0.86 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRQ74 is the taller of the two 7.6 mm dual-winding parts at 4.35 mm, so it carries more current than DRQ73 in the same footprint. Two windings, series or parallel, 1:1 coupling when you want a transformer instead of a choke.
100 uH sits in the middle of the range, and the trade at that point is explicit: 383 mOhm of DCR against 0.99 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd