| Parameter | Value |
|---|---|
| Orderable part number | DRQ74-471-R |
| Rated inductance | 470 uH ±20% |
| Open circuit inductance (OCL) | 465 uH |
| Irms (40 °C rise) | 0.4 A |
| Isat | 0.46 A |
| DCR typical @ 20 °C | 1740 mOhm |
| Volt-microsecond rating | 68.1 V-us |
| Series connection | 1861 uH, 0.2 A |
| Parallel connection | 470 uH, 0.4 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.
Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRQ74 is the taller of the two 7.6 mm dual-winding parts at 4.35 mm, so it carries more current than DRQ73 in the same footprint. Two windings, series or parallel, 1:1 coupling when you want a transformer instead of a choke.
470 uH sits in the middle of the range, and the trade at that point is explicit: 1740 mOhm of DCR against 0.46 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd