| Parameter | Value |
|---|---|
| Orderable part number | ECMS1V0704-302-R |
| Impedance minimum @ 100 MHz | 2,500 Ohm |
| Impedance typical @ 100 MHz | 3,000 Ohm |
| DCR maximum @ +25 °C | 75 mOhm |
| Rated current maximum | 0.9 A |
| Rated voltage maximum | 80 Vdc |
| Insulation resistance minimum | 10 MOhm |
| Package | 8.0 x 6.5 mm footprint, 3.8 mm height, up to 15 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
A common-mode choke works by cancellation: the two supply lines pass through windings wound so that differential current produces no net flux, while common-mode noise - the current that returns through earth or leaks across insulation - sees the full impedance of the core. This part is built for exactly that job at high frequency, on a square closed magnetic core that keeps the field inside the body.
Impedance is quoted at 100 MHz with the windings in parallel - the frequency band where switching harmonics actually radiate. The minimum column is the guaranteed production limit; the typical column is what most parts deliver.
The DCR sits in the power path, so every milliohm is loss on the supply lines: 75 mOhm maximum at 0.9 A is a deliberate trade the family makes against impedance in the same footprint.
The typical and the maximum DCR are both quoted for a reason: production spread. A loss budget that has to hold across a build uses 75 mOhm as the optimistic case and plans against the maximum.
ECMS is the surface-mount common-mode family for battery-powered, renewable energy, smart meter and industrial equipment: high-frequency filtering on a closed square core, with current ratings up to 15 A across the three footprints.
Does DC bias affect the impedance?
Modestly. The core is sized so that the rated current does not saturate the path, but large unbalanced DC shifts the operating point - keep the lines balanced.
Will it filter differential noise?
Only through leakage; common-mode chokes are not differential filters. Pair with an X-capacitor for differential noise.
Does DC bias affect the impedance?
Modestly. The core is sized so that the rated current does not saturate the path, but large unbalanced DC shifts the operating point - keep the lines balanced.
Design note: pick the impedance from the noise band you need to attenuate, then verify the rated current covers the DC on both lines combined.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.