| Parameter | Value |
|---|---|
| Orderable part number | ECMS1V0704-700-R |
| Impedance minimum @ 100 MHz | 40 Ohm |
| Impedance typical @ 100 MHz | 70 Ohm |
| DCR maximum @ +25 °C | 5 mOhm |
| Rated current maximum | 15 A |
| Rated voltage maximum | 80 Vdc |
| Insulation resistance minimum | 10 MOhm |
| Package | 8.0 x 6.5 mm footprint, 3.8 mm height, up to 15 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
A common-mode choke works by cancellation: the two supply lines pass through windings wound so that differential current produces no net flux, while common-mode noise - the current that returns through earth or leaks across insulation - sees the full impedance of the core. This part is built for exactly that job at high frequency, on a square closed magnetic core that keeps the field inside the body.
Impedance is quoted at 100 MHz with the windings in parallel - the frequency band where switching harmonics actually radiate. The minimum column is the guaranteed production limit; the typical column is what most parts deliver.
The DCR sits in the power path, so every milliohm is loss on the supply lines: 5 mOhm maximum at 15 A is a deliberate trade the family makes against impedance in the same footprint.
Copper loss is the efficiency floor. 5 mOhm at 25 °C rises about 30% by 100 °C, so the hot-corner budget should use the maximum column, not the typical.
ECMS is the surface-mount common-mode family for battery-powered, renewable energy, smart meter and industrial equipment: high-frequency filtering on a closed square core, with current ratings up to 15 A across the three footprints.
Will it filter differential noise?
Only through leakage; common-mode chokes are not differential filters. Pair with an X-capacitor for differential noise.
Why is there a rated voltage for a choke?
The maximum working voltage on the lines the choke sits between. Exceeding it stresses the winding insulation.
Does DC bias affect the impedance?
Modestly. The core is sized so that the rated current does not saturate the path, but large unbalanced DC shifts the operating point - keep the lines balanced.
Design note: pick the impedance from the noise band you need to attenuate, then verify the rated current covers the DC on both lines combined.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd