| Parameter | Value |
|---|---|
| Orderable part number | ECMS1V0905-301-R |
| Impedance minimum @ 100 MHz | 225 Ohm |
| Impedance typical @ 100 MHz | 300 Ohm |
| DCR maximum @ +25 °C | 6 mOhm |
| Rated current maximum | 6 A |
| Rated voltage maximum | 80 Vdc |
| Insulation resistance minimum | 10 MOhm |
| Package | 10 x 7.5 mm footprint, 4.8 mm height, up to 6 A |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Where a single line needs a differential choke and the board has no room for a filter stage, the common-mode choke is the efficient answer: two windings, one core, and the noise path attenuated in a single component.
Impedance is quoted at 100 MHz with the windings in parallel - the frequency band where switching harmonics actually radiate. The minimum column is the guaranteed production limit; the typical column is what most parts deliver.
The DCR sits in the power path, so every milliohm is loss on the supply lines: 6 mOhm maximum at 6 A is a deliberate trade the family makes against impedance in the same footprint.
At 6 mOhm the winding dominates the loss budget at load. The moulded construction spreads that heat into the body, but the board the part sits on still decides the actual temperature rise.
ECMS is the surface-mount common-mode family for battery-powered, renewable energy, smart meter and industrial equipment: high-frequency filtering on a closed square core, with current ratings up to 15 A across the three footprints.
Will it filter differential noise?
Only through leakage; common-mode chokes are not differential filters. Pair with an X-capacitor for differential noise.
What is the MSL rating?
Moisture sensitivity level 1 - unlimited floor life before reflow.
What does the impedance number mean?
It is the impedance the choke presents to common-mode noise at 100 MHz, measured with the windings in parallel at +25 °C. The minimum is the guaranteed value; the typical is the centre of the distribution.
Design note: pick the impedance from the noise band you need to attenuate, then verify the rated current covers the DC on both lines combined.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.