| Parameter | Value |
|---|---|
| Orderable part number | ECMT1V1714H-150-R |
| OCL minimum, (1-2) & (4-3) | 15 mH |
| DCR maximum @ +25 °C, (1-2) & (4-3) | 0.6 Ohm |
| Irms per winding, (1-4) short | 1 A |
| SRF minimum | 408 kHz |
| Hi-pot, coil-to-core | 1500 Vac, 2 s, 5 mA |
| Hi-pot, coil-to-coil | 1000 Vac, 2 s, 5 mA |
| Insulation resistance minimum | 100 MOhm |
| Rated voltage | 250 Vac |
| Package | through-hole, closed magnetic path, rated 250 Vac |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
Two windings, one closed core, and isolation ratings measured both coil-to-coil and coil-to-core: this is a common-mode inductor built for industrial IoT equipment, motion controls and renewable energy products rather than for consumer boards.
The two winding sections are specified separately because a mismatch turns common-mode noise into differential noise. The Hi-pot figures are quoted coil-to-core and coil-to-coil - both are functional isolation ratings, and the 250 Vac rated voltage governs what lines the part may sit between.
Irms is rated per winding with the section short-circuited, which is the harshest thermal case for a common-mode inductor: the whole winding carries the current with no cancellation to help.
Copper loss is the efficiency floor. 600 mOhm at 25 °C rises about 30% by 100 °C, so the hot-corner budget should use the maximum column, not the typical.
ECMT is the through-hole common-mode family for industrial power equipment - motion controls, power supplies, solar and wind inverters, chargers - where high isolation and a robust soldered filter point matter more than board area.
Why are there two OCL columns?
The two winding sections are measured separately, (1-2) and (4-3). Mismatch between them turns common-mode noise into differential noise.
What are the two Hi-pot ratings?
Coil-to-core and coil-to-coil isolation, each tested for 2 seconds at 5 mA. They are functional isolation ratings for circuit architecture, not safety barriers.
Can I use it on a DC line?
The rated voltage is 250 Vac for the winding insulation; large unbalanced DC on the lines biases the core and reduces the impedance. Keep the lines balanced.
Design note: the SRF column is a minimum; the choke stops filtering above it. Match the part to the noise band, not just to the inductance.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd