| Parameter | Value |
|---|---|
| Orderable part number | ECMT1V1714H-300-R |
| OCL minimum, (1-2) & (4-3) | 30 mH |
| DCR maximum @ +25 °C, (1-2) & (4-3) | 1.6 Ohm |
| Irms per winding, (1-4) short | 0.6 A |
| SRF minimum | 276 kHz |
| Hi-pot, coil-to-core | 1500 Vac, 2 s, 5 mA |
| Hi-pot, coil-to-coil | 1000 Vac, 2 s, 5 mA |
| Insulation resistance minimum | 100 MOhm |
| Rated voltage | 250 Vac |
| Package | through-hole, closed magnetic path, rated 250 Vac |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
High impedance and high inductance in a through-hole body: this part exists for power electronics where the noise spectrum is broad and the replacement cycle is measured in years. The independent winding sections mean each line is filtered without cross-talk between them.
The two winding sections are specified separately because a mismatch turns common-mode noise into differential noise. The Hi-pot figures are quoted coil-to-core and coil-to-coil - both are functional isolation ratings, and the 250 Vac rated voltage governs what lines the part may sit between.
Irms is rated per winding with the section short-circuited, which is the harshest thermal case for a common-mode inductor: the whole winding carries the current with no cancellation to help.
At 1600 mOhm the winding dominates the loss budget at load. The moulded construction spreads that heat into the body, but the board the part sits on still decides the actual temperature rise.
ECMT is the through-hole common-mode family for industrial power equipment - motion controls, power supplies, solar and wind inverters, chargers - where high isolation and a robust soldered filter point matter more than board area.
What is the SRF column for?
The self-resonant frequency is where the winding capacitance cancels the inductance; above it the choke stops being an inductor. Pick a part whose SRF sits above your noise band.
What is the SRF column for?
The self-resonant frequency is where the winding capacitance cancels the inductance; above it the choke stops being an inductor. Pick a part whose SRF sits above your noise band.
Why are there two OCL columns?
The two winding sections are measured separately, (1-2) and (4-3). Mismatch between them turns common-mode noise into differential noise.
Design note: the SRF column is a minimum; the choke stops filtering above it. Match the part to the noise band, not just to the inductance.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd