
| Parameter | Value |
|---|---|
| Orderable part number | ECMT1V2429S-300-R |
| OCL minimum, (1-2) & (4-3) | 30 mH |
| DCR maximum @ +25 °C, (1-2) & (4-3) | 1.6 Ohm |
| Irms per winding, (1-4) short | 0.6 A |
| SRF minimum | 276 kHz |
| Hi-pot, coil-to-core | 1500 Vac, 2 s, 5 mA |
| Hi-pot, coil-to-coil | 1000 Vac, 2 s, 5 mA |
| Insulation resistance minimum | 100 MOhm |
| Rated voltage | 250 Vac |
| Package | through-hole, closed magnetic path, rated 250 Vac |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
A through-hole common-mode inductor with a closed magnetic path: the two independent winding sections share a ferrite core, differential current cancels, and common-mode noise sees the full inductance. Built for equipment where the filter point is a soldered, high-isolation component rather than a replaceable cartridge.
The two winding sections are specified separately because a mismatch turns common-mode noise into differential noise. The Hi-pot figures are quoted coil-to-core and coil-to-coil - both are functional isolation ratings, and the 250 Vac rated voltage governs what lines the part may sit between.
Irms is rated per winding with the section short-circuited, which is the harshest thermal case for a common-mode inductor: the whole winding carries the current with no cancellation to help.
At 1600 mOhm the winding dominates the loss budget at load. The moulded construction spreads that heat into the body, but the board the part sits on still decides the actual temperature rise.
ECMT is the through-hole common-mode family for industrial power equipment - motion controls, power supplies, solar and wind inverters, chargers - where high isolation and a robust soldered filter point matter more than board area.
Can I use it on a DC line?
The rated voltage is 250 Vac for the winding insulation; large unbalanced DC on the lines biases the core and reduces the impedance. Keep the lines balanced.
Why are there two OCL columns?
The two winding sections are measured separately, (1-2) and (4-3). Mismatch between them turns common-mode noise into differential noise.
Can I use it on a DC line?
The rated voltage is 250 Vac for the winding insulation; large unbalanced DC on the lines biases the core and reduces the impedance. Keep the lines balanced.
Design note: the SRF column is a minimum; the choke stops filtering above it. Match the part to the noise band, not just to the inductance.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd