| Parameter | Value |
|---|---|
| Orderable part number | ECMT1V2429S-5R0-R |
| OCL minimum, (1-2) & (4-3) | 5 mH |
| DCR maximum @ +25 °C, (1-2) & (4-3) | 0.3 Ohm |
| Irms per winding, (1-4) short | 1.4 A |
| SRF minimum | 712 kHz |
| Hi-pot, coil-to-core | 1500 Vac, 2 s, 5 mA |
| Hi-pot, coil-to-coil | 1000 Vac, 2 s, 5 mA |
| Insulation resistance minimum | 100 MOhm |
| Rated voltage | 250 Vac |
| Package | through-hole, closed magnetic path, rated 250 Vac |
| Mounting | Through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |

Drawings from the Eaton data sheet: mechanical outline with rated mm dimensions, recommended PCB pad layout, and winding schematic. Tolerances and pad tolerances are stated on the drawing itself.
The construction is deliberately robust: separate winding sections, a closed magnetic path that reduces conducted emission, and coil-to-coil and coil-to-core isolation ratings specified separately. It is the choke you put on the input of industrial power equipment and then forget about.
The two winding sections are specified separately because a mismatch turns common-mode noise into differential noise. The Hi-pot figures are quoted coil-to-core and coil-to-coil - both are functional isolation ratings, and the 250 Vac rated voltage governs what lines the part may sit between.
Irms is rated per winding with the section short-circuited, which is the harshest thermal case for a common-mode inductor: the whole winding carries the current with no cancellation to help.
DCR 300 mOhm is the conduction loss: at rated current it dissipates 0.00 W, and that heat has to leave through the terminals and the board.
ECMT is the through-hole common-mode family for industrial power equipment - motion controls, power supplies, solar and wind inverters, chargers - where high isolation and a robust soldered filter point matter more than board area.
What are the two Hi-pot ratings?
Coil-to-core and coil-to-coil isolation, each tested for 2 seconds at 5 mA. They are functional isolation ratings for circuit architecture, not safety barriers.
Why through-hole?
Mechanical robustness and serviceability: the part survives handling, high vibration and wave soldering, which suits industrial power equipment.
Can I use it on a DC line?
The rated voltage is 250 Vac for the winding insulation; large unbalanced DC on the lines biases the core and reduces the impedance. Keep the lines balanced.
Design note: the SRF column is a minimum; the choke stops filtering above it. Match the part to the noise band, not just to the inductance.