| Parameter | Value |
|---|---|
| Orderable part number | ECST1V0504-1030-R |
| Turns ratio secondary:primary | 30:1 |
| Secondary inductance minimum | 74 uH |
| DCR secondary maximum | 800 mOhm |
| DCR primary reference | 3 mOhm |
| Hi-pot primary to secondary | 500 Vac |
| Sensed current maximum | 7 A |
| Package | 4.8 x 3.65 x 3.55 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1185 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1185; the package line above gives the body size where
the data sheet states it.
A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.
With a 30:1 ratio, a 10 A primary current becomes 0.333 A in the secondary. Across a 50 ohm burden that is 16.7 V, which is what the controller actually sees.
The secondary winding of 74 uH with 800 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.
Within the ECST1V0504 family this is item 2 of 9 in the Eaton catalogue.
The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.
How much current can the primary take?
The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.
What turns ratio do I need?
Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.
Is the part AEC-Q200 qualified?
The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.