Eaton ECST1V0504-1040-R Current Sense Transformer, 7 A
Eaton ECST1V0504-1040-R Current Sense Transformer, 7 A

Eaton ECST1V0504-1040-R Current Sense Transformer, 7 A

Share
ECST1V0504-1040-R: current sense transformer, 132 uH, 40:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0504-1040-R Current Sense Transformer, 7 A

    ECST1V0504-1040-R at a glance: current sense transformer, 132 uH, 40:1 turns ratio, 7 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECST1V0504-1040-R
    Turns ratio secondary:primary40:1
    Secondary inductance minimum132 uH
    DCR secondary maximum1.6 Ohm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1185

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1185; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The primary is a single turn – often just a trace or a busbar through the part – and the secondary is the wound coil. That is why the primary DCR is quoted in milliohm and the secondary DCR in ohm: the two sides are built completely differently.

    With a 40:1 ratio, a 10 A primary current becomes 0.25 A in the secondary. Across a 50 ohm burden that is 12.5 V, which is what the controller actually sees.

    The secondary winding of 132 uH with 1600 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0504 family this is item 3 of 9 in the Eaton catalogue.

    Series Positioning

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.