Eaton ECST1V0504-1060-R Current Sense Transformer 60:1
Eaton ECST1V0504-1060-R Current Sense Transformer 60:1

Eaton ECST1V0504-1060-R Current Sense Transformer 60:1

Share
ECST1V0504-1060-R: current sense transformer, 295 uH, 60:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0504-1060-R Current Sense Transformer 60:1

    ECST1V0504-1060-R at a glance: current sense transformer, 295 uH, 60:1 turns ratio, 7 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECST1V0504-1060-R
    Turns ratio secondary:primary60:1
    Secondary inductance minimum295 uH
    DCR secondary maximum3.6 Ohm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1185

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1185; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 60:1 ratio, a 10 A primary current becomes 0.167 A in the secondary. Across a 50 ohm burden that is 8.33 V, which is what the controller actually sees.

    The secondary winding of 295 uH with 3600 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0504 family this is item 5 of 9 in the Eaton catalogue.

    Where This Series Fits

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.