Eaton ECST1V0805-1020-R Current Sense Transformer, 10 A
Eaton ECST1V0805-1020-R Current Sense Transformer, 10 A

Eaton ECST1V0805-1020-R Current Sense Transformer, 10 A

Share
ECST1V0805-1020-R: current sense transformer, 80 uH, 20:1 turns ratio, 10 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0805-1020-R Current Sense Transformer, 10 A

    ECST1V0805-1020-R at a glance: current sense transformer, 80 uH, 20:1 turns ratio, 10 A sensed.

    Key Specifications

    ParameterValue
    Orderable part numberECST1V0805-1020-R
    Turns ratio secondary:primary20:1
    Secondary inductance minimum80 uH
    DCR secondary maximum400 mOhm
    DCR primary reference0.7 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum10 A
    Package8.38 x 8 x 5.5 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1187

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1187; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The primary is a single turn – often just a trace or a busbar through the part – and the secondary is the wound coil. That is why the primary DCR is quoted in milliohm and the secondary DCR in ohm: the two sides are built completely differently.

    With a 20:1 ratio, a 10 A primary current becomes 0.5 A in the secondary. Across a 50 ohm burden that is 25 V, which is what the controller actually sees.

    The secondary winding of 80 uH with 400 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0805 family this is item 1 of 8 in the Eaton catalogue.

    Positioning in the Range

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.