Eaton ECST1V0805-1050-R SMT Current Transformer 50:1
Eaton ECST1V0805-1050-R SMT Current Transformer 50:1

Eaton ECST1V0805-1050-R SMT Current Transformer 50:1

Share
ECST1V0805-1050-R: current sense transformer, 500 uH, 50:1 turns ratio, 10 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0805-1050-R SMT Current Transformer 50:1

    ECST1V0805-1050-R at a glance: current sense transformer, 500 uH, 50:1 turns ratio, 10 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECST1V0805-1050-R
    Turns ratio secondary:primary50:1
    Secondary inductance minimum500 uH
    DCR secondary maximum1.85 Ohm
    DCR primary reference0.7 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum10 A
    Package8.38 x 8 x 5.5 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1187

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1187; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 50:1 ratio, a 10 A primary current becomes 0.2 A in the secondary. Across a 50 ohm burden that is 10 V, which is what the controller actually sees.

    The secondary winding of 500 uH with 1850 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0805 family this is item 4 of 8 in the Eaton catalogue.

    Positioning in the Range

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message