| Parameter | Value |
|---|---|
| Orderable part number | ECST1V0805-1125-R |
| Turns ratio secondary:primary | 125:1 |
| Secondary inductance minimum | 3000 uH |
| DCR secondary maximum | 11.5 Ohm |
| DCR primary reference | 0.7 mOhm |
| Hi-pot primary to secondary | 500 Vac |
| Sensed current maximum | 10 A |
| Package | 8.38 x 8 x 5.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1187 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1187; the package line above gives the body size where
the data sheet states it.
This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.
With a 125:1 ratio, a 10 A primary current becomes 0.08 A in the secondary. Across a 50 ohm burden that is 4 V, which is what the controller actually sees.
The secondary winding of 3000 uH with 11500 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.
Within the ECST1V0805 family this is item 8 of 8 in the Eaton catalogue.
The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.
Why must the secondary be terminated?
The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.
How much current can the primary take?
The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.
How much current can the primary take?
The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.