ECST1V1308-1060-R: current sense transformer, 2000 uH, 60:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECST1V1308-1060-R Current Sense Transformer, 15 A

    ECST1V1308-1060-R at a glance: current sense transformer, 2000 uH, 60:1 turns ratio, 15 A sensed.

    Ratings at a Glance

    ParameterValue
    Orderable part numberECST1V1308-1060-R
    Turns ratio secondary:primary60:1
    Secondary inductance minimum2000 uH
    DCR secondary maximum810 mOhm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1188

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1188; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 60:1 ratio, a 10 A primary current becomes 0.167 A in the secondary. Across a 50 ohm burden that is 8.33 V, which is what the controller actually sees.

    The secondary winding of 2000 uH with 810 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V1308 family this is item 5 of 11 in the Eaton catalogue.

    Positioning in the Range

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.