Eaton ECSTA1V0504-1040-R Current Transformer 40:1
Eaton ECSTA1V0504-1040-R Current Transformer 40:1

Eaton ECSTA1V0504-1040-R Current Transformer 40:1

Share
ECSTA1V0504-1040-R: current sense transformer, 132 uH, 40:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0504-1040-R Current Transformer 40:1

    ECSTA1V0504-1040-R at a glance: current sense transformer, 132 uH, 40:1 turns ratio, 7 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V0504-1040-R
    Turns ratio secondary:primary40:1
    Secondary inductance minimum132 uH
    DCR secondary maximum1.6 Ohm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1189

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1189; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.

    With a 40:1 ratio, a 10 A primary current becomes 0.25 A in the secondary. Across a 50 ohm burden that is 12.5 V, which is what the controller actually sees.

    The secondary winding of 132 uH with 1600 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0504 family this is item 3 of 9 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message