Eaton ECSTA1V0504-1060-R SMT Current Transformer 60:1
Eaton ECSTA1V0504-1060-R SMT Current Transformer 60:1

Eaton ECSTA1V0504-1060-R SMT Current Transformer 60:1

Share
ECSTA1V0504-1060-R: current sense transformer, 295 uH, 60:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0504-1060-R SMT Current Transformer 60:1

    ECSTA1V0504-1060-R at a glance: current sense transformer, 295 uH, 60:1 turns ratio, 7 A sensed.

    Key Specifications

    ParameterValue
    Orderable part numberECSTA1V0504-1060-R
    Turns ratio secondary:primary60:1
    Secondary inductance minimum295 uH
    DCR secondary maximum3.6 Ohm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1189

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1189; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 60:1 ratio, a 10 A primary current becomes 0.167 A in the secondary. Across a 50 ohm burden that is 8.33 V, which is what the controller actually sees.

    The secondary winding of 295 uH with 3600 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0504 family this is item 5 of 9 in the Eaton catalogue.

    Where This Series Fits

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.