Eaton ECSTA1V0703-1020-R Current Sense Transformer, 9 A
Eaton ECSTA1V0703-1020-R Current Sense Transformer, 9 A

Eaton ECSTA1V0703-1020-R Current Sense Transformer, 9 A

Share
ECSTA1V0703-1020-R: current sense transformer, 53 uH, 20:1 turns ratio, 9 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0703-1020-R Current Sense Transformer, 9 A

    ECSTA1V0703-1020-R at a glance: current sense transformer, 53 uH, 20:1 turns ratio, 9 A sensed.

    Ratings at a Glance

    ParameterValue
    Orderable part numberECSTA1V0703-1020-R
    Turns ratio secondary:primary20:1
    Secondary inductance minimum53 uH
    DCR secondary maximum420 mOhm
    DCR primary reference1.5 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum9 A
    Package7.2 x 5.2 x 3 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1190

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1190; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    The primary is a single turn – often just a trace or a busbar through the part – and the secondary is the wound coil. That is why the primary DCR is quoted in milliohm and the secondary DCR in ohm: the two sides are built completely differently.

    With a 20:1 ratio, a 10 A primary current becomes 0.5 A in the secondary. Across a 50 ohm burden that is 25 V, which is what the controller actually sees.

    The secondary winding of 53 uH with 420 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0703 family this is item 1 of 5 in the Eaton catalogue.

    Positioning in the Range

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.