Eaton ECSTA1V0703-1050-R Current Transformer 50:1
Eaton ECSTA1V0703-1050-R Current Transformer 50:1

Eaton ECSTA1V0703-1050-R Current Transformer 50:1

Share
ECSTA1V0703-1050-R: current sense transformer, 333 uH, 50:1 turns ratio, 9 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0703-1050-R Current Transformer 50:1

    ECSTA1V0703-1050-R at a glance: current sense transformer, 333 uH, 50:1 turns ratio, 9 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V0703-1050-R
    Turns ratio secondary:primary50:1
    Secondary inductance minimum333 uH
    DCR secondary maximum2.76 Ohm
    DCR primary reference1.5 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum9 A
    Package7.2 x 5.2 x 3 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1190

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1190; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The primary is a single turn – often just a trace or a busbar through the part – and the secondary is the wound coil. That is why the primary DCR is quoted in milliohm and the secondary DCR in ohm: the two sides are built completely differently.

    With a 50:1 ratio, a 10 A primary current becomes 0.2 A in the secondary. Across a 50 ohm burden that is 10 V, which is what the controller actually sees.

    The secondary winding of 333 uH with 2760 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0703 family this is item 2 of 5 in the Eaton catalogue.

    Series Positioning

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.