Eaton ECSTA1V0703-1070-R Current Sense Transformer 70:1
Eaton ECSTA1V0703-1070-R Current Sense Transformer 70:1

Eaton ECSTA1V0703-1070-R Current Sense Transformer 70:1

Share
ECSTA1V0703-1070-R: current sense transformer, 652 uH, 70:1 turns ratio, 9 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0703-1070-R Current Sense Transformer 70:1

    ECSTA1V0703-1070-R at a glance: current sense transformer, 652 uH, 70:1 turns ratio, 9 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V0703-1070-R
    Turns ratio secondary:primary70:1
    Secondary inductance minimum652 uH
    DCR secondary maximum5.04 Ohm
    DCR primary reference1.5 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum9 A
    Package7.2 x 5.2 x 3 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1190

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1190; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 70:1 ratio, a 10 A primary current becomes 0.143 A in the secondary. Across a 50 ohm burden that is 7.14 V, which is what the controller actually sees.

    The secondary winding of 652 uH with 5040 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0703 family this is item 3 of 5 in the Eaton catalogue.

    Positioning in the Range

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.