ECSTA1V0703-1100-R: current sense transformer, 1330 uH, 100:1 turns ratio, 9 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0703-1100-R SMT Current Transformer 100:1

    ECSTA1V0703-1100-R at a glance: current sense transformer, 1330 uH, 100:1 turns ratio, 9 A sensed.

    Specification Table

    ParameterValue
    Orderable part numberECSTA1V0703-1100-R
    Turns ratio secondary:primary100:1
    Secondary inductance minimum1330 uH
    DCR secondary maximum10.7 Ohm
    DCR primary reference1.5 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum9 A
    Package7.2 x 5.2 x 3 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1190

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1190; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 100:1 ratio, a 10 A primary current becomes 0.1 A in the secondary. Across a 50 ohm burden that is 5 V, which is what the controller actually sees.

    The secondary winding of 1330 uH with 10680 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0703 family this is item 4 of 5 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.