Eaton ECSTA1V0805-1030-R Current Sense Transformer 30:1
Eaton ECSTA1V0805-1030-R Current Sense Transformer 30:1

Eaton ECSTA1V0805-1030-R Current Sense Transformer 30:1

Share
ECSTA1V0805-1030-R: current sense transformer, 180 uH, 30:1 turns ratio, 10 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0805-1030-R Current Sense Transformer 30:1

    ECSTA1V0805-1030-R at a glance: current sense transformer, 180 uH, 30:1 turns ratio, 10 A sensed.

    Ratings at a Glance

    ParameterValue
    Orderable part numberECSTA1V0805-1030-R
    Turns ratio secondary:primary30:1
    Secondary inductance minimum180 uH
    DCR secondary maximum870 mOhm
    DCR primary reference0.7 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum10 A
    Package8.38 x 8 x 5.5 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1191

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1191; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 30:1 ratio, a 10 A primary current becomes 0.333 A in the secondary. Across a 50 ohm burden that is 16.7 V, which is what the controller actually sees.

    The secondary winding of 180 uH with 870 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0805 family this is item 2 of 8 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message