Eaton ECSTA1V1308-1050-R Current Sense Transformer, 15 A
Eaton ECSTA1V1308-1050-R Current Sense Transformer, 15 A

Eaton ECSTA1V1308-1050-R Current Sense Transformer, 15 A

Share
ECSTA1V1308-1050-R: current sense transformer, 1400 uH, 50:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V1308-1050-R Current Sense Transformer, 15 A

    ECSTA1V1308-1050-R at a glance: current sense transformer, 1400 uH, 50:1 turns ratio, 15 A sensed.

    Specification Table

    ParameterValue
    Orderable part numberECSTA1V1308-1050-R
    Turns ratio secondary:primary50:1
    Secondary inductance minimum1400 uH
    DCR secondary maximum650 mOhm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1192

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1192; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 50:1 ratio, a 10 A primary current becomes 0.2 A in the secondary. Across a 50 ohm burden that is 10 V, which is what the controller actually sees.

    The secondary winding of 1400 uH with 650 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V1308 family this is item 4 of 11 in the Eaton catalogue.

    Where This Series Fits

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.