Eaton EPM25751V-12R-R62D 18-75V Input Isolated Converter
Eaton EPM25751V-12R-R62D 18-75V Input Isolated Converter

Eaton EPM25751V-12R-R62D 18-75V Input Isolated Converter

Share
EPM25751V-12R-R62D: Isolated DC-DC Converter, 18-75 V input, ±12 V output, ±625 mA, 7.5 W, 89.50 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25751V-12R-R62D 18-75V Input Isolated Converter

    EPM25751V-12R-R62D at a glance: Isolated DC-DC Converter, 18-75 V input, ±12 V output, ±625 mA, 7.5 W, 89.50 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM25751V-12R-R62D
    Input voltage range18-75 Vdc (nominal 48 V)
    Output voltage±12 Vdc
    Output current at full load±625 mA
    Output power7.5 W
    Efficiency, minimum88.50 %
    Efficiency, typical89.50 %
    Capacitive load, maximum520 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1165

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1165.

    Reading the Data Sheet

    Efficiency runs from 84 to 92 percent depending on the output voltage: the low rails lose more in the rectifiers, the high rails lose more in the turns ratio. The data sheet gives both minimum and typical so the loss budget can be built on either.

    At 7.5 W out and 89.50 % typical efficiency the module dissipates about 0.88 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    What does the wide input range buy me?
    A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    What does the wide input range buy me?
    A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.