Eaton EPM25751V-15R-1R0S 15 W Isolated DC-DC Converter
Eaton EPM25751V-15R-1R0S 15 W Isolated DC-DC Converter

Eaton EPM25751V-15R-1R0S 15 W Isolated DC-DC Converter

Share
EPM25751V-15R-1R0S: Isolated DC-DC Converter, 18-75 V input, 15 V output, 1000 mA, 15 W, 89.50 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25751V-15R-1R0S 15 W Isolated DC-DC Converter

    EPM25751V-15R-1R0S at a glance: Isolated DC-DC Converter, 18-75 V input, 15 V output, 1000 mA, 15 W, 89.50 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM25751V-15R-1R0S
    Input voltage range18-75 Vdc (nominal 48 V)
    Output voltage15 Vdc
    Output current at full load1000 mA
    Output power15 W
    Efficiency, minimum88.50 %
    Efficiency, typical89.50 %
    Capacitive load, maximum900 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1165

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1165.

    What the Numbers Mean

    A quarter-brick style isolated converter: 9-36 V or 18-75 V input, single or dual output from 3.3 V to 24 V, 15 to 60 W. The 2 x 1 inch package and the wide input range are what make it a drop-in for industrial and telecom rails.

    At 15 W out and 89.50 % typical efficiency the module dissipates about 1.76 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    Does it need a minimum load?
    No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Does it need a minimum load?
    No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.