
| Parameter | Value |
|---|---|
| Orderable part number | EPM25751V-15R-2R0S |
| Input voltage range | 18-75 Vdc (nominal 48 V) |
| Output voltage | 15 Vdc |
| Output current at full load | 2000 mA |
| Output power | 30 W |
| Efficiency, minimum | 89.50 % |
| Efficiency, typical | 90.50 % |
| Capacitive load, maximum | 1000 uF |
| Isolation voltage | 1.6 kVdc |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1166 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1166.
A quarter-brick style isolated converter: 9-36 V or 18-75 V input, single or dual output from 3.3 V to 24 V, 15 to 60 W. The 2 x 1 inch package and the wide input range are what make it a drop-in for industrial and telecom rails.
At 30 W out and 90.50 % typical efficiency the module dissipates about 3.15 W. That is the number the thermal design has to carry, not the output power.
The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.
How is the case cooled?
Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.
Can I trim the output?
The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.
What does the wide input range buy me?
A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd