Eaton EPM25751V-3R3-4R0S 3.3V 13.2W DC-DC Module
Eaton EPM25751V-3R3-4R0S 3.3V 13.2W DC-DC Module

Eaton EPM25751V-3R3-4R0S 3.3V 13.2W DC-DC Module

Share
EPM25751V-3R3-4R0S: Isolated DC-DC Converter, 18-75 V input, 3.3 V output, 4000 mA, 13.2 W, 85.00 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25751V-3R3-4R0S 3.3V 13.2W DC-DC Module

    EPM25751V-3R3-4R0S at a glance: Isolated DC-DC Converter, 18-75 V input, 3.3 V output, 4000 mA, 13.2 W, 85.00 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM25751V-3R3-4R0S
    Input voltage range18-75 Vdc (nominal 48 V)
    Output voltage3.3 Vdc
    Output current at full load4000 mA
    Output power13.2 W
    Efficiency, minimum84.00 %
    Efficiency, typical85.00 %
    Capacitive load, maximum12000 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1165

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1165.

    Reading the Data Sheet

    The module takes a wide input (4:1 range) and holds the output across it, which is what a 24 V or 48 V industrial bus needs when the battery sags. Isolation is 1.6 kVdc, and the case is the heatsink.

    At 13.2 W out and 85.00 % typical efficiency the module dissipates about 2.33 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    Does it need a minimum load?
    No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.

    What does the wide input range buy me?
    A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products