Eaton EPM25752V-05R-12RS 5V 60W DC-DC Module
Eaton EPM25752V-05R-12RS 5V 60W DC-DC Module

Eaton EPM25752V-05R-12RS 5V 60W DC-DC Module

Share
EPM25752V-05R-12RS: Isolated DC-DC Converter, 18-75 V input, 5 V output, 12000 mA, 60 W, 91 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25752V-05R-12RS 5V 60W DC-DC Module

    EPM25752V-05R-12RS at a glance: Isolated DC-DC Converter, 18-75 V input, 5 V output, 12000 mA, 60 W, 91 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM25752V-05R-12RS
    Input voltage range18-75 Vdc (nominal 48 V)
    Output voltage5 Vdc
    Output current at full load12000 mA
    Output power60 W
    Efficiency, minimum90 %
    Efficiency, typical91 %
    Capacitive load, maximum28000 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1168

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1168.

    What the Numbers Mean

    A quarter-brick style isolated converter: 9-36 V or 18-75 V input, single or dual output from 3.3 V to 24 V, 15 to 60 W. The 2 x 1 inch package and the wide input range are what make it a drop-in for industrial and telecom rails.

    At 60 W out and 91 % typical efficiency the module dissipates about 5.93 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd