Eaton EPM6051V-15R-067SH Isolated Converter 15V Out
Eaton EPM6051V-15R-067SH Isolated Converter 15V Out

Eaton EPM6051V-15R-067SH Isolated Converter 15V Out

Share
EPM6051V-15R-067SH: Isolated DC-DC Converter, 5 V input, 15 V output, 67 mA, 1.01 W, 83 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6051V-15R-067SH Isolated Converter 15V Out

    EPM6051V-15R-067SH at a glance: Isolated DC-DC Converter, 5 V input, 15 V output, 67 mA, 1.01 W, 83 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM6051V-15R-067SH
    Input voltage range5 Vdc
    Output voltage15 Vdc
    Output current at full load67 mA
    Output power1.01 W
    Efficiency, minimum80 %
    Efficiency, typical83 %
    Capacitive load, maximum220 uF
    Isolation voltage1 kVdc
    Isolation optionH = higher isolation voltage
    PackageSIP
    Operating temperature-40 °C to +90 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1162

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1162.

    The Figures Explained

    Isolated modules like this appear wherever a signal has to cross a barrier: RS-485 transceivers, gate drivers, medical front ends, current shunt amplifiers. The 1 W rating is the continuous output; the input current at no load is a separate line in the data sheet.

    At 1.005 W out and 83 % typical efficiency the module dissipates about 0.21 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.