Eaton EPM6051V-3R3-303SH 3.3V 303mA Isolated DC-DC
Eaton EPM6051V-3R3-303SH 3.3V 303mA Isolated DC-DC

Eaton EPM6051V-3R3-303SH 3.3V 303mA Isolated DC-DC

Share
EPM6051V-3R3-303SH: Isolated DC-DC Converter, 5 V input, 3.3 V output, 303 mA, 1 W, 74 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6051V-3R3-303SH 3.3V 303mA Isolated DC-DC

    EPM6051V-3R3-303SH at a glance: Isolated DC-DC Converter, 5 V input, 3.3 V output, 303 mA, 1 W, 74 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM6051V-3R3-303SH
    Input voltage range5 Vdc
    Output voltage3.3 Vdc
    Output current at full load303 mA
    Output power1 W
    Efficiency, minimum71 %
    Efficiency, typical74 %
    Capacitive load, maximum1500 uF
    Isolation voltage1 kVdc
    Isolation optionH = higher isolation voltage
    PackageSIP
    Operating temperature-40 °C to +90 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1162

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1162.

    How to Read These Ratings

    These modules are chosen for isolation first and power second. One watt at 70 to 85 percent efficiency is not a thermal problem; the questions are the isolation voltage, the regulation across the load range and whether the output can start into a capacitive load.

    At 0.9999 W out and 74 % typical efficiency the module dissipates about 0.35 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    Does it need external capacitors?
    The data sheet recommends input and output capacitors to meet the ripple figure. The module runs without them, but not to specification.

    Can the output be paralleled?
    Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.