| Parameter | Value |
|---|---|
| Orderable part number | EPM6052V-3R3-303SR |
| Input voltage range | 5 Vdc |
| Output voltage | 3.3 Vdc |
| Output current at full load | 303 mA |
| Output power | 1 W |
| Efficiency, minimum | 71 % |
| Efficiency, typical | 74 % |
| Capacitive load, maximum | 1500 uF |
| Isolation voltage | 3 kVdc |
| Package | SIP |
| Operating temperature | -40 °C to +100 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1163 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1163.
The module runs from a fixed input and produces ±V with no external parts. The isolation option in the part number selects standard or higher isolation voltage, which is the difference between the R and H suffixes.
At 0.9999 W out and 74 % typical efficiency the module dissipates about 0.35 W. That is the number the thermal design has to carry, not the output power.
The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.
How good is the negative rail?
Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.
How good is the negative rail?
Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.
What is the difference between the R and H suffix?
The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.