| Parameter | Value |
|---|---|
| Orderable part number | EPM6121V-05R-200SR |
| Input voltage range | 12 Vdc |
| Output voltage | 5 Vdc |
| Output current at full load | 200 mA |
| Output power | 1 W |
| Efficiency, minimum | 79 % |
| Efficiency, typical | 82 % |
| Capacitive load, maximum | 1500 uF |
| Isolation voltage | 1 kVdc |
| Isolation option | R = standard isolation |
| Package | SIP |
| Operating temperature | -40 °C to +90 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1162 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1162.
These modules are chosen for isolation first and power second. One watt at 70 to 85 percent efficiency is not a thermal problem; the questions are the isolation voltage, the regulation across the load range and whether the output can start into a capacitive load.
At 1 W out and 82 % typical efficiency the module dissipates about 0.22 W. That is the number the thermal design has to carry, not the output power.
The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.
Why is the no-load input current specified?
Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.
What does the isolation voltage mean in practice?
It is the test voltage the barrier withstands, not a continuous working voltage. For reinforced insulation you also need the creepage on the board, which the module cannot provide on its own.
Can the output be paralleled?
Not directly. Two isolated modules will not share current without droop sharing or a series resistor, because their output voltages differ by the tolerance band.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd