Eaton EPM6241V-05R-200SH Isolated Converter 5V Out
Eaton EPM6241V-05R-200SH Isolated Converter 5V Out

Eaton EPM6241V-05R-200SH Isolated Converter 5V Out

Share
EPM6241V-05R-200SH: Isolated DC-DC Converter, 24 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6241V-05R-200SH Isolated Converter 5V Out

    EPM6241V-05R-200SH at a glance: Isolated DC-DC Converter, 24 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.

    Key Specifications

    ParameterValue
    Orderable part numberEPM6241V-05R-200SH
    Input voltage range24 Vdc
    Output voltage5 Vdc
    Output current at full load200 mA
    Output power1 W
    Efficiency, minimum76 %
    Efficiency, typical79 %
    Capacitive load, maximum1500 uF
    Isolation voltage1 kVdc
    Isolation optionH = higher isolation voltage
    PackageSIP
    Operating temperature-40 °C to +90 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1162

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1162.

    How to Read These Ratings

    A one-watt isolated DC-DC module in a SIP or DIP footprint: 5, 12 or 24 V in, single or dual output out, with galvanic isolation between the two sides. It is the part that breaks a ground loop or floats a gate driver supply when a full converter would be overkill.

    At 1 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.

    What This Family Is For

    The 1 W isolated range covers 5, 12 and 24 V inputs with single or dual outputs from 3.3 V to 15 V, in SIP and DIP packages with standard or high isolation.

    • The isolation barrier is only as good as the board creepage around it. Check the pad spacing, not just the module rating.

    Frequently Asked Questions

    What does the isolation voltage mean in practice?
    It is the test voltage the barrier withstands, not a continuous working voltage. For reinforced insulation you also need the creepage on the board, which the module cannot provide on its own.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Why is the no-load input current specified?
    Because a 1 W module can draw 20 to 30 mA with nothing connected. In a battery-powered design that idle current can be the dominant loss.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products